Parkside PKO 24 B2 Air Compressor Spare Parts: Repair and Maintain Your Machine

Are you looking for a spare part for your Parkside PKO 24 B2 air compressor to repair your equipment, replace a worn component or solve an operating problem? At Probois Machinoutils, we offer a selection of replacement parts for the maintenance and repair of your Parkside PKO24B2 air compressor.

Used for various DIY tasks, inflation, blowing and operating certain compatible pneumatic accessories, this compressor requires appropriate maintenance to preserve its performance.

Like any machine producing compressed air, it contains mechanical, pneumatic and electrical components that may wear over time. Pressure variations, vibrations, operating temperatures and working conditions can gradually affect certain parts.

Our catalogue includes Parkside compressor gaskets, piston rings, cylinder heads, pressure switches, pressure gauges, safety valves, pneumatic fittings, plugs and various protective components.

These parts can help repair many common faults, provided that the defective component is correctly identified and its compatibility with the exact version of your compressor is confirmed.

Parkside PKO 24 B2 Compressor: Identify Your Exact Model

The Parkside PKO 24 B2 belongs to the range of air compressors marketed under the Parkside brand. It is important not to confuse it with other versions, particularly the PKO 24 A1, PSKO 24 A1 or the different PKO 270 models.

Although some compressors may share similar components, their spare parts are not necessarily interchangeable.

Differences may concern dimensions, mounting arrangements, pneumatic connections, electrical specifications or internal components of the compression unit.

Before ordering a spare part for Parkside PKO24B2, we recommend checking the complete model reference shown on your machine's identification plate.

The IAN number, serial number and manufacturing date may also help identify a particular production version.

If you have access to the compressor's exploded parts diagram, locate the position number of the component you need to replace and compare the corresponding references.

Air Filter for Parkside Compressor

The compressor air filter helps prevent dust and particles from entering the compression unit.

A clogged filter may restrict airflow and affect compressor operation. Its condition should therefore be checked regularly, especially when the machine is used in dusty environments.

Our catalogue includes an air filter for various Scheppach and Parkside compressors.

Before selecting a replacement filter, check its dimensions, connection type and the compatible models listed on its product page.

The presence of a filter in this category does not guarantee compatibility with every Parkside compressor version. Checking the original part reference remains essential.

Cylinder Head for Parkside Compressor: An Essential Compression Component

The compressor cylinder head is an important component of the compression unit. It helps close the upper section of the cylinder and manage airflow passages according to the machine's design.

A damaged cylinder head may cause air leakage, reduced performance or abnormal compressor operation.

Our catalogue includes cylinder head reference 3906129001, listed for several Parkside compressors, including the PKO 270 A4, PKO 500 A2 and PKO 24 A1 models according to the product compatibility information.

Before ordering this component for a PKO 24 B2, it is therefore essential to confirm its exact compatibility.

Replacing a cylinder head also requires checking the gaskets, mating surfaces and other components of the compression unit.

A new cylinder head will not necessarily solve a pressure problem if the fault originates from worn piston rings, a defective valve or another internal component.

Piston Rings for Parkside PKO 24 B2 Compressor

Compressor piston rings help maintain the seal between the piston and cylinder. They play an essential role in the efficiency of the compression unit.

When piston rings become worn, cracked or damaged, compressor performance may gradually decrease.

Several symptoms may appear:

  • Slower pressure build-up than usual.
  • Longer operating times to fill the receiver tank.
  • Reduced compression unit performance.
  • Abnormal operation accompanied by other signs of mechanical wear.

We offer a set of three piston rings for Parkside compressors, intended for the models specified on the corresponding product page.

Before replacing them, it is necessary to inspect the condition of the cylinder, piston and contact surfaces.

Significant cylinder wear may mean that replacing the piston rings alone is insufficient.

Cylinder Head Gasket and Crankcase Gasket for Parkside Compressor

Gaskets for Parkside PKO 24 B2 compressors provide sealing between different mechanical sections of the compression unit.

A damaged gasket may cause air leakage, reduced efficiency or oil seepage, depending on its location.

Our catalogue includes:

  • Crankcase gasket reference 3906129008, corresponding to position 18 on certain exploded parts diagrams.
  • Cylinder head gasket listed for various Scheppach, Parkside and Zipper compressors, corresponding to position 4 on certain diagrams and replacing the previous reference 5906101003.

Each gasket has specific dimensions, thickness and shape. It is therefore essential to select the correct component for its exact location on the compressor.

During reassembly, mating surfaces must be clean and in good condition. The manufacturer's instructions concerning gasket positioning and tightening of fasteners must be followed.

An incorrectly installed gasket may cause further leakage and affect compressor operation.

Pressure Switch for Parkside PKO24B2 Compressor

The compressor pressure switch automatically controls motor operation according to the air pressure inside the receiver tank.

It allows the compressor to start when pressure falls below a specified threshold and stop when the required pressure is reached.

A faulty pressure switch may cause several problems:

  • The compressor no longer starts normally.
  • The motor fails to restart after a pressure drop.
  • Automatic operation becomes irregular.
  • The motor control system behaves unusually.

Our selection includes pressure switch reference 3906129013, listed for various Scheppach, Zipper and Parkside compressors.

Before replacing this component, check the electrical specifications, connections and operating pressure limits required for your machine.

A starting problem is not necessarily caused by the pressure switch. It may also be related to the motor, electrical supply or another component.

Pressure settings must never be modified to exceed the limits specified by the manufacturer.

Pressure Gauge for Parkside Compressor

The pressure gauge allows the user to monitor air pressure in the circuit to which it is connected.

It is an important component for checking compressor operation and using pneumatic accessories under suitable conditions.

A damaged pressure gauge may have a stuck needle, display incorrect readings or develop an air leak around its connection.

We offer a 42 mm pressure gauge with G 1/8" threaded connection, reference 5906102003, for various Scheppach and Parkside compressors according to the compatibility information.

Before ordering, check the dial diameter, thread type, measuring range and connection orientation.

The pressure scale may vary depending on the version supplied by the manufacturer. Always consult the product specifications.

Safety Valve for Parkside PKO 24 B2 Compressor

The compressor safety valve is an essential protective component of the pressurised system.

Its purpose is to help protect the equipment against excessive pressure, in accordance with the specifications defined by the manufacturer.

A damaged safety valve, one that leaks or no longer operates correctly, requires particular attention.

Our catalogue includes a safety valve under references 3906140001 or 4906116075, listed for various Scheppach, Woodstar and Parkside compressors depending on the model.

Replacing a safety valve requires checking its pressure rating, technical specifications and connections.

A safety valve must never be blocked, bypassed, modified or replaced with a model having an unsuitable pressure setting.

If there is any doubt about its operation, the compressor should be inspected by a qualified person before being used again.

Quick Coupling and Pneumatic Elbow for Parkside Compressor

Pneumatic fittings connect different parts of the compressed air circuit and allow compatible accessories to be attached.

A damaged quick coupling may cause air leakage, poor connection or difficulties attaching a pneumatic hose.

Our catalogue includes a quick coupling for Scheppach, Woodster, Zipper and Parkside compressors, corresponding to positions 57 or 58 on certain exploded parts diagrams.

We also offer a pneumatic elbow reference 3906129026, intended for various Scheppach, Woodstar and Parkside compressors according to the compatibility information.

These components must be selected according to their thread type, dimensions and position on the machine.

A component with a similar connection is not necessarily compatible with the original pneumatic circuit.

Before replacing a fitting, the circuit must be completely depressurised and the manufacturer's installation instructions followed.

Oil Plug and Tank Plug for Parkside Compressor

Plugs for Parkside compressors perform different functions depending on their location on the machine.

Some close an opening in the oil crankcase, while others seal a specific opening in the pneumatic system or receiver tank.

Our catalogue includes several components:

  • Oil filler plug for various Scheppach and Parkside compressors.
  • Oil level plug listed for Parkside PKO 500 A2, PKO 270 A4 and PKO 24 A1 compressors.
  • Plug with O-ring reference 3906123007, also described as a tank screw for various Scheppach and Woodster compressors.

Before ordering one of these parts for your PKO 24 B2, check its compatibility, dimensions and mounting arrangement.

A plug with a crack, damaged thread or worn seal may cause leakage.

Components fitted to a pressurised circuit must always meet the machine's technical specifications.

Rubber Foot and Motor Cover for Parkside PKO24B2 Compressor

External compressor components also play an important role in stability and protection.

Rubber feet help stabilise the machine and reduce the transmission of certain vibrations to the supporting surface.

A worn or missing foot may result in poor stability, additional vibrations or abnormal movement of the compressor during operation.

We offer rubber foot reference 3906129018, listed for Parkside PKO 24 A1, PKO 24 B2, PKO 270 A4 and PKO 500 A2 compressors.

Our catalogue also includes motor cover reference 3906140008, listed for various Scheppach and Parkside compressor models.

The cover helps protect certain motor components. It must be correctly secured and must not be removed while the machine is in use.

Replacing a damaged foot or motor cover can help maintain suitable operating conditions.

Why Is My Parkside PKO 24 B2 Compressor Not Building Pressure?

A Parkside PKO24B2 compressor that no longer builds pressure may have several different faults.

Possible causes include:

  • Air leakage from a pneumatic fitting.
  • Poor sealing around a plug or another circuit component.
  • A damaged cylinder head gasket.
  • Worn piston rings.
  • A defective valve.
  • Wear affecting the compression unit.
  • A malfunction in the control system.

It is important to distinguish between a machine that no longer produces sufficient pressure and a compressor that fails to start altogether.

In the first case, the problem may be related to air leakage or loss of compression. In the second case, it may be necessary to check the electrical supply, pressure switch or motor.

An unusual reading on the pressure gauge does not necessarily mean that the compression unit is defective.

Accurate diagnosis helps avoid unnecessary replacements and ensures that the correct component is selected.

How to Find the Correct Spare Part for Parkside PKO 24 B2

To order a spare part compatible with your Parkside PKO 24 B2 compressor, several checks are recommended.

  • Identify the exact model: check the PKO 24 B2 reference on the identification plate.
  • Record the IAN number: this information may help distinguish specific production versions.
  • Consult the exploded parts diagram: identify the position number of the required component.
  • Compare part references: check manufacturer codes and any superseded references.
  • Check dimensions: particularly for gaskets, fittings, plugs and mechanical components.
  • Verify technical specifications: especially for electrical components and safety devices.

Some components are shared by several Parkside, Scheppach, Woodster or Zipper compressors, but compatibility must never be assumed without verification.

Each product page provides information to help identify the required reference.

Regular Maintenance of Your Parkside PKO 24 B2 Air Compressor

Regular maintenance helps preserve compressor performance and reduce the risk of certain faults.

All maintenance operations must be carried out according to the manufacturer's instructions.

Common checks include:

  • Checking the oil level regularly according to the operating manual.
  • Inspecting the air filter and replacing it when necessary.
  • Draining condensate from the receiver tank regularly.
  • Checking accessible pneumatic connections for air leaks.
  • Checking the proper operation of the pressure gauges.
  • Inspecting the condition of the power cable and switch.
  • Keeping ventilation openings clean and unobstructed.
  • Checking rubber feet and protective covers.
  • Respecting the manufacturer's operating limits and duty cycle.

Before any maintenance or repair, disconnect the compressor from the electrical supply, allow it to cool and completely depressurise the relevant circuit.

As the receiver tank is a pressure vessel, it must never be drilled, welded or repaired using improvised methods. Any damage that could affect its structural integrity requires appropriate assessment.

Safety devices must always remain operational and must never be disabled.

Why Repair Your Parkside Compressor Instead of Replacing It?

When an air compressor develops a fault, purchasing a completely new machine is not always necessary.

If the malfunction is caused by an identifiable and replaceable component, a repair may help extend the service life of your equipment.

Replacing a gasket, quick coupling, pressure gauge, rubber foot or another suitable component can be an economical solution when the rest of the machine remains in good condition.

Repairing your compressor can also help reduce waste and limit the expense associated with replacing workshop equipment.

However, the cost of repair, the overall condition of the machine and safety requirements must always be considered.

Repairs involving the motor, electrical system, compression unit or safety devices should be carried out by someone with the necessary technical skills.

Buy Parkside PKO 24 B2 Compressor Spare Parts at Probois Machinoutils

Probois Machinoutils specialises in the sale of machinery, workshop equipment, accessories and spare parts for numerous brands.

We offer a developing range of spare parts for Parkside PKO 24 B2 air compressors to help you maintain and repair your machine.

This category includes cylinder head gaskets, crankcase gaskets, piston rings, cylinder heads, pressure switches, pressure gauges, safety valves, quick couplings, pneumatic elbows, plugs, rubber feet and motor covers.

Available references may change depending on stock levels and parts availability from manufacturers.

Before ordering, carefully read each product description and check that the component is suitable for your compressor version.

Whether you are looking for a gasket for Parkside PKO24B2 compressor, a Parkside pressure switch, a replacement pressure gauge, a safety valve or a mechanical component for the compression unit, our catalogue helps you identify the references that meet your requirements.

By choosing a compatible spare part and following the manufacturer's maintenance recommendations, you can help preserve the performance of your Parkside PKO 24 B2 air compressor and extend its service life.